10.05.D
XT33 Series DISK RECORDER – Version 10.05 - Software Technical Reference
EVS Broadcast Equipment SA – July 2011
Important note 1:
The SD phase is always adjusted according to the SDI outputs. Internal
CVBS outputs have a delay of 48 x 37
corresponding SDI outputs.
Important note 2:
The internal CVBS outputs cannot be used to feed directly a vision mixer
or any equipment performing video effects, since the phase of the chroma
subcarrier is not adjustable internally.
1.5.8 DEFAULT APPLICATION
This option is used to define the default application that is automatically started
by the system. Every time the EVS software is entered, the default application is
started a few seconds later. You can avoid the automatic start by pressing the
<SPACE BAR> or the UP ARROW and DOWN ARROW keys immediately when
entering the EVS software. If no default application has been defined, the system
will remain in the EVS software.
The default application is shown against a black background in the Application
window.
HOW TO DEFINE A DEFAULT APPLICATION
• In the Application window, select the new default application using the
UP ARROW and DOWN ARROW keys and press F7
OR:
• Call the Maintenance menu with F9 and select ‘Default Application’, select the
defined application from the list, and press ENTER
o If a default application was already defined, a message warns the operator
that it will be disabled. The command can be confirmed with ENTER or
cancelled with ESC.
o If the command is confirmed, another message warns the operator that a
new default application has just been defined.
HOW TO REMOVE THE DEFAULT APPLICATION
• In the Application window, select the application that is the current default
application (blue characters with black background) using the UP ARROW and
DOWN ARROW keys, and press F7.
OR:
• Call the Maintenance menu with F9 and select ‘Default Application‘. Then
select the current default application from the list and press ENTER.
A message warns the operator that the current default application will be
disabled. The command can be confirmed with ENTER or cancelled with ESC.