EVS XT2+ Bedienungsanleitung Seite 111

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 234
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 110
OSD
Description Specifies which device (main or secondary controller) will
manage the OSD display characters in parallel mode.
Values Two values are possible:
Main: The OSD display is managed by the main controller.
Sec.: The OSD display is managed by the secondary
controller.
Rules for Controller Assignment
Main Rules for XT2+ server
On an XT2+ server, the following main rules are applicable:
In a Multicam LSM base configuration:
All Remote Panels must be the first in the list of main controllers, without gap. It is
not allowed to have another controller preceding a Remote Panel in this list.
Other controllers can be assigned as secondary controllers to PGMs taking into
account the protocol-specific rules.
No more than 4 play channels on an EVS server can be assigned to Remote
Panels, and no more than 3 play channels can be assigned to one Remote Panel.
Only a Remote Panel (no other controller) can be assigned to a REC channel as a
main controller.
No secondary controller can be assigned to a REC channel.
In a Spotbox or Server base configuration:
A Remote Panel is not allowed.
Controllers other than the EVS Remote can be assigned to play or record
channels, taking into account the protocol-specific rules on controller use and
combinations.
101 3. Multicam Configuration
EVS Broadcast Equipment S.A. - November 2012 Issue 11.01.B
Seitenansicht 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 233 234